Comprehensive Fault Analysis

The DAPPER Comprehensive Fault Analysis program provides a network solution of three-phase, single-line to ground, line-to line, and double line to ground fault currents; RMS momentary fault currents; asymmetrical fault duties at three, five, and eight cycles; the positive, negative, and zero sequence impedance values between each fault location, and contributions from utilities, generators, and motors. At each fault location, the direction, X/R, and magnitude of fault currents are reported, thus providing a clear view of the conditions that exist during the fault.

Features

  • Symmetrical and Asymmetrical values reported at 1/2, 3, 5, and 8 cycles.
  • Asymmetrical values reported at user selected fault time.
  • Asymmetrical values reported as peak or RMS values.
  • Models two and three winding transformer taps, phase shift, and off nominal rated voltages.
  • Asymmetrical exponential DC decay is based on X/R to each contribution.
  • Reports Thevenin equivalent impedance and X/R at the faulted bus.
  • Detailed and summary reporting options.
  • Reports bus voltages and branch flows throughout the system for each faulted bus.
  • Reports phase or sequence current and voltage.
  • Reports ground return current for double line to ground faults.
  • Models transformer and generator neutral grounding impedances.

Related Products:

Bender ISO685

View Product

Bender ISOMETER IRDH275

View Product

Bender ISOMETER IRDH375

View Product

Bender ISOMETER IRDH575

View Product

Bender ISOMETER isoPV with AGH-PV

View Product

Bender ISOMETER isoPV425 with AGH420

View Product

Bender ISOMETER isoPV1685

View Product

Bender ISOMETER isoMED427P

View Product

doblePRIME PD-Guard

View Product

doblePRIME DOMINO

View Product

Satir Hotfind-S

View Product

SATIR PK80

View Product

Satir D300

View Product

Satir D600

View Product

Satir G96

View Product

Satir CK350VN

View Product

Satir UAV 640P

View Product

Satir V-Series Gas Detection Camera

View Product

BE1-11f, Feeder Protection System

View Product

Load Flow / Voltage Drop

View Product

Comprehensive Fault Analysis

View Product

Demand Load Analysis

View Product

Feeder And Transformer Sizing

View Product

Load Schedules

View Product

Captor Study Module

View Product

Arc Flash Evaluation Studies

View Product

DC System Analysis Module

View Product

Arc Flash Hazard Calculator

View Product

doblePRIME IDD

View Product

Merus A2-Series

View Product

doblePRIME

View Product

Bender LINETRAXX PEM735

View Product

Bender LINETRAXX PEM575

View Product

Bender LINETRAXX PEM555

View Product

Bender LINETRAXX PEM333/330

View Product

Bender ISOSCAN EDS440

View Product

Bender ISOSCAN EDS460/EDS461

View Product

Bender ISOSCAN EDS490D/EDS491D

View Product

Bender ISOSCAN EDS3090PG Portable Insulation Fault Locator

View Product

Bender LINETRAXX RCMS460-D

View Product

Bender LINETRAXX RCSM490-D

View Product

Bender LINETRAXX VME420

View Product

Bender LINETRAXX VMD421

View Product

Bender LINETRAXX VMD460-NA

View Product

Bender LINETRAXX CME420

View Product

Bender LINETRAXX CMS460-D

View Product

Bender COMTRAXX MK2430 Medical Alarm Indicator

View Product

Bender ES710 Medical Isolation Transformer

View Product

ES Series Protection Relays

View Product

DECS-400 Digital Excitation Control System

View Product

DECS-2100 Digital Excitation Control System

View Product

DECS-250E, Digital Excitation Control System

View Product

DECS-400, Digital Excitation Control System

View Product

SMC-250, Synchronous Motor Controller

View Product

SGC-250, Synchronous Generator Controller

View Product

Calisto 2

View Product

Calisto 5

View Product

Calisto 9

View Product

Myrkos Field Package

View Product

Myrkos Lab Package

View Product

Myrkos – Portable MicroGC

View Product